Excel-Coat K/D (K/D II also
included)
Guide Specification
Decorative
Protection for Concrete
NOTES TO SPECIFIER: This is a general
specification which includes the various finishes that may be achieved with
Excel-Coat K/D products. The K/D refers to a Knock-Down finish.
“K/D II”
includes the Tape and Trowel, Tape Trowel & Skin and the Stamping. When
specifying these finishes you will want to reference “K/D II and then select the
appropriate finish Materials in Section 2.01 and the corresponding Installation
in Section 3.02.
PART I -
GENERAL
1.01
SYSTEM DESCRIPTION
A. The Excel-Coat K/D (or K/D II) system is designed to be a colorful,
decorative, skid resistant coating to protect and beautify pool decks, concrete
walkways, patios and entryways.
1.02
SCOPE
A. Work Included
1. Preparation of substrate.
2. Preparation of cracks and joints.
3. Application of the Excel-Coat K/D (or K/D II) System.
B. Related Work Specified Elsewhere
1. Concrete Finishing Division 3
2. Sealants Division 7
1.03
QUALITY ASSURANCE
A. The materials that compose the Excel-Coat K/D (or K/D II) System are
manufactured and furnished by Excellent Coatings, Inc.
1.04
SUBMITTALS
A. Samples: Applicator must provide a 2” x 2” sample board showing design,
texture and color for approval.
B. Product Data: Provide manufacturer's written data sheet, detail drawings,
maintenance instructions and cleaning Instructions.
1.05
DELIVERY, STORAGE & HANDLING
A. Delivery: Materials shall be delivered to the job site in sealed,
undamaged containers. Each container shall be clearly marked with manufacturer's
label showing type of material, expiration date, color and batch number.
B. Storage: Store all Excel-Coat materials in a cool dry place with a
temperature range of 55°F to 9O° F.
C. Handling: Handle all products carefully to avoid damage to the
containers. Read all labels and Material Safety Data Sheets prior to use.
1.06
PROJECT JOBSITE CONDITIONS
A. Before any work is started, the applicator shall inspect all surfaces for
any deficiencies. Should any deficiencies exist, the Architect, Owner or General
Contractor shall be notified in writing and any corrections necessary shall be
made.
B. No coating shall be applied during inclement weather or when the
temperature falls below 55°F or rises above 95°F.
1.07
WARRANTY
A. A warranty for the Excel-Coat K/D (or K/D II) System is available upon
request from the Owner or Owner's Representative prior to the
installation of the deck coating system. Once all inspections (before, during
and after the installation) have been completed, Excellent Coatings, Inc. will
issue a written warranty and maintenance program. This warranty covers the
product performance of the deck coating only. Liability for damage to property,
buildings, and their contents or to any third party is specifically excluded.
PART 2 -
PRODUCTS
2.01
MATERIALS FOR THE SYSTEM (select accordingly)
A. Excel-Coat
K/D Knock-Down System
1. Primer: Excel-Coat Primer PC-155
2. Slurry Coat: Excel-Crete K/D & Tinted Additive
3. Texture Coat: Excel-Crete K/D and Excel-Crete Tinted Additive (add
Excel-Crete Retarder as needed)
4. Top Coat: Excel-Coat K/D Color Sealer, Excel-Coat Glaze or Acrylic
Lacquer Sealer
B. Excel-Coat
K/D II Tape & Trowel System
1. Primer: Excel-Coat Primer PC-155
2. Slurry Coat: Excel-Crete K/D & Tinted Additive
3. Texture Coat: Excel-Crete K/D and Excel-Crete Tinted Additive (add
Excel-Crete Retarder as needed)
4. Top Coat: Excel-Coat Glaze or Excel-Coat Acrylic Lacquer Sealer
C. Excel-Coat
K/D II Tape, Trowel & Skin System
1. Primer: Excel-Coat Primer PC-155
2. Slurry Coat: Excel-Crete K/D & Tinted Additive
3. Texture Coat: Excel-Crete K/D and Excel-Crete Tinted Additive
4. Excel-Crete Retarder
5. Excel-Coat Fibers
6. Excel-Coat MERT Sealer
7. Excel-Coat Release Agent
8. Excel-Coat Antiquing Powder(s)
9. Top Coat: Excel-Coat Glaze or Excel-Coat Acrylic Lacquer Sealer
D. Excel-Coat
K/D II Stamping System
1. Primer: Excel-Coat Primer PC-155
2. Slurry Coat: Excel-Crete K/D & Tinted Additive
3. Texture Coat: Excel-Crete K/D and Excel-Crete Tinted Additive
4. Excel-Crete Retarder
5. Excel-Coat Fibers
6. Excel-Coat MERT Sealer
7. Excel-Coat Release Agent
8. Excel-Coat Antiquing Powder(s)
9. Top Coat: Excel-Coat Glaze or Excel-Coat Acrylic Lacquer Sealer
E. Related
Materials
1. Urethane sealant
2. Excel-Coat Patching Compound
3. Epoxy Crack Repair Material
PART 3 -
EXECUTION
3.01
INSPECTION
A. General
1. Concrete surface shall be free of excess roughness, voids, protrusions,
loose particles, dust or debris. Poorly finished concrete may telegraph through
the Excel-Coat K/D (or K/D II) System.
2. Concrete surface must be free from curing agents, bond-breakers,
hardeners, oils, grease or foreign matter that may affect the adhesion of the
Excel-Coat K/D (or K/D II) System.
3. Concrete substrate shall be designed and constructed as to freely drain
and eliminate the ponding of water. Slope: 1/4" per foot.
4. Concrete moisture content shall not exceed 10%. Moisture Vapor
Transmission shall not exceed 5 lbs. per square ft. per 24 hours.
B. New Concrete
1. Curing of concrete shall be by means of water-cure or dissipating
compounds. Curing compounds to be used shall be approved by an authorized
representative of Excellent Coatings, Inc.
2. Concrete shall be cured a minimum of 28 days prior to installation of
Excel-Coat K/D (or K/D II) System.
3. Concrete shall be finished with a power metal float followed by a light
steel trowel and medium hair broom or equivalent.
4. Concrete moisture content shall not exceed 10%. Moisture Vapor
Transmission shall not exceed 5 lbs. per square ft. per 24 hours.
C. Old Concrete
1. The following are effective means of cleaning and preparing old concrete
prior to the application of Excel-Coat K/D (or K/D II ):
a. Surface
Grinding: A heavy
duty, industrial grinder may be used to clean and abrade the concrete when the
surface is dry. Loose particles and dust must then be removed by vacuum or
blower.
b. Shot
Blasting and Sand Blasting:
These are both effective means of cleaning concrete surfaces. Before coating,
area must be free from dust or any loose particles.
c. Acid Etching:
A solution of commercial muriatic acid and water (3 parts water: 1 part muriatic
acid) is also a satisfactory method of cleaning concrete. Pour solution over
concrete surface and agitate with stiff bristle broom or brush. The solution
will react with the concrete causing it to bubble. Once the bubbling has
stopped, power -wash the deck with water to rinse away residual salts and
contaminants. To ensure complete neutralization of the concrete surface, the
deck may be brushed with alkali solution (1% ammonia in water) and then rinsed.
d. Commercial
Detergents:
Commercial detergents, such as Trisodium Phosphate (TSP), will work well to
clean light grease and grime, but these products are not recommended for heavy
contamination.
D. Concrete Patching
1. Repairs to old or new concrete may be necessary to correct minor
imperfections in the surface (i.e. low spots, holes, ridges and protrusions).
2. All repair areas shall be cleaned as described above, then filled with
Excel-Crete Patching and Sloping Compound for repairs less than 1/8 inch in
thickness. Refer to Excel-Crete Data Sheet for repairs that are greater than
1/8 inch in thickness. Excel-Crete repairs shall cure for a minimum of 24 hours
prior to Excel-Coat K/D (or K/D II) system application.
3. Small spalled areas may be repaired with a two-part semi-rigid epoxy.
E. Expansion Joints & Cracks
1. Expansion joints shall be cleaned thoroughly and sealed with urethane
sealant.
2. Cracks over 1/16“shall be routed, primed and repaired with an epoxy crack
repair material.
3.02
INSTALLATION (Select Installation for appropriate system that is to be used.
Selection shall correspond with 2.01)
A. Excel-Coat
K/D Knock-Down Finish: Read and follow instructions in manufacturer’s Application Guide.
1. Apply Excel-Coat Primer 120 or PC-155 to concrete at a rate of 250 square
feet per gallon.
2. Slurry Coat: Using a drill motor mix Excel-Crete K/D with Excel-Crete
Tinted Additive. Apply with a trowel to consistence thickness approximately
1/16 “. Allow material to dry 2- 6 hours. Dry times may vary.
3. Mix texture coat and apply using a hopper. To create a knock-down finish,
follow the texture application with a steel finishing trowel. Careful and
consistent measuring of products helps to ensure color uniformity. Excel-Crete
Retarder may be added to mix to prolong workability of product in the hopper.
For best results, allow the texture to begin to dry (1-15 minutes) before
knocking down with trowel. Allow 24 hours to dry.
4. With a wallboard scraper, lightly scrape off any irregularities in the
texture. Use a blower to clean the deck area of any remaining dirt or debris.
5. Apply two thin coats of Excel-Coat K/D Color Sealer, Excel-Coat Glaze or
Excel-Coat Acrylic Lacquer Sealer by roller or airless sprayer at a rate of 250
square ft. per gallon per coat, for a net yield of 125 square ft. per gallon
total coverage. Allow dry 4 hours to dry before applying second coat.
6. Allow completed system to cure 24 hours before heavy-foot traffic is
permitted and an additional 72 hours before heavy objects are placed on the
surface.
B. Excel-Coat
K/D II Tape and Trowel: Read and follow
instructions in manufacturer’s Data Sheet / Application Guide.
1. Apply Excel-Coat Primer 120 or PC-155 to concrete at a rate of 250 square
feet per gallon.
2. Slurry Coat (Grout Coat): Mix Excel-Crete K/D with Tinted Additive.
Apply with a trowel to a thickness of approximately 1/16-1/8 inch in thickness.
Allow material to dry 2- 6 hours. Dry times may vary.
3. Place and apply stencil or tape patterned. Ensure stencil or tape is
properly adhered.
4. Mix Excel-Crete with Tinted Additive. Excel-Crete Retarder may be added
to extended workability time. Apply texture coat over the taped surfaces.
Coverage will vary depending upon the type of texture that is being applied.
Allow material to dry.
5. Apply Antiquing or Excel-Crete Tinted Additive to highlight as needed.
Allow highlighting to thoroughly dry.
6. Carefully remove grout tape once Excel-Crete has cured. Use a grinding
stone to smooth edges and/or rough spots
7. Apply two thin coats of Excel-Coat Glaze or Excel-Coat Acrylic Lacquer
Sealer by roller or airless sprayer at a rate of 250 square ft. per gallon per
coat, for a net yield of 125 square ft. per gallon total coverage. Allow 4 hours
to dry before applying the second seal coat.
8. Allow completed system to cure 24 hours before heavy-foot traffic is
permitted and an additional 72 hours before heavy objects are placed on the
surface.
C. Excel-Coat
K/D II Tape, Trowel & Skin:
Read and follow instructions in manufacturer’s Data Sheet / Application Guide.
1. Apply Excel-Coat Primer 120 or PC-155 to concrete at a rate of 250 square
feet per gallon.
2. Slurry Coat (Grout Coat): Mix Excel-Crete K/D with Tinted Additive.
Apply with a trowel to a thickness of approximately 1/16-1/8 inch in
thickness. Allow material to dry 8 hours hours. Dry times may vary.
3. Place and apply stencil or tape patterned. Ensure stencil or tape is
properly adhered.
4. Apply MERT Sealer to seal tape or stencil and two inches on either side.
Allow protective seal coat to dry 1-2 hours.
5. Thoroughly mix Excel-Crete K/D with Excel-Crete Tinted Additive,
Excel-Crete Retarder and Excel-Coat Fibers. Apply texture coat to a workable
amount of area over the taped surfaces. Coverage will vary depending upon the
type of texture that is being applied. This application shall be a minimum of
1/8” when using skins.
6. While Excel-Crete is wet, lightly spray Excel-Coat Release Agent onto
both the wet Excel-Crete and textured side of skin(s).
7. Place skin and using pounder or linoleum roller ensure desired impression
is made then remove promptly. Continue this process over the area to receive
coating. Allow texture Excel-Crete to cure.
8. Apply Antiquing or Excel-Crete Tinted Additive to highlight as needed.
Allow highlighting to thoroughly dry.
9. Carefully remove grout tape once Excel-Crete has cured. Use a grinding
stone to smooth edges and/or rough spots
10. Apply two thin coats of Excel-Coat Acrylic Lacquer Sealer by roller or
airless sprayer at a rate of 250 square ft. per gallon per coat, for a net yield
of 125 square ft. per gallon total coverage. Allow 4 hours to dry before
applying the second seal coat.
11. Allow completed system to cure 24 hours before heavy-foot traffic is
permitted and an additional 72 hours before heavy objects are placed on the
surface.
D. Excel-Coat
K/D II Stamping:
Read and follow instructions in manufacturer’s Data Sheet / Application Guide.
1. Apply Excel-Coat Primer 120 or PC-155 to concrete at a rate of 250 square
feet per gallon.
2. Thoroughly mix Excel-Crete K/D with Excel-Crete Tinted Additive,
Excel-Crete Retarder and Fibers. Apply texture coat to a workable amount of
area over the taped surfaces. Coverage will vary depending upon the type of
texture that is being applied. This application shall be a minimum of 1/4’ when
using stamps.
3. While Excel-Crete is wet, lightly spray apply Excel-Coat Release Agent
onto both the wet Excel-Crete and textured side of stamp(s).
4. Place stamp and using pounder or linoleum roller ensure desired
impression is made then remove promptly. Continue this process over the area to
receive coating. Allow texture Excel-Crete to cure.
5. Apply Antiquing or Excel-Crete Tinted Additive to highlight as needed.
Allow highlighting to thoroughly dry.
6. Apply two thin coats of Excel-Coat Acrylic Lacquer Sealer by roller or
airless sprayer at a rate of 250 square ft. per gallon per coat, for a net yield
of 125 square ft. per gallon total coverage. Allow 4 hours to dry before
applying the second seal coat.
7. Allow completed system to cure 24 hours before heavy-foot traffic is
permitted and an additional 72 hours before heavy objects are placed on the
surface.
3.03
CLEAN UP
A. Clean area and remove all debris upon completion of work. Dispose of
empty containers properly according to current Local, State and Federal
regulations.
NOTE: The
Excel-Coat K/D (or K/D II) System may be combined with our Excel-Coat Waterproof
Systems to provide unbeatable waterproof protection with unlimited decorative
possibilities. K/D & K/D II finishes may be applied over Excel-Coat Pedestrian
Traffic Membrane (concrete substrates only) and over the Excel-Coat Fire System
membrane.
1/04
|